Filters

Filters

Impression Copings

IMPRESSION COPINGS

COST-VALUE EFFECTIVE
WORLDWIDE SHIPPING
WIDE PRODUCT SELECTION
QUALITY MATERIALS
LEADING BRAND COMPATIBILITY
Impression Copings

Impression Copings

COST-VALUE EFFECTIVE
WORLDWIDE SHIPPING
WIDE PRODUCT SELECTION
QUALITY MATERIALS
LEADING BRAND COMPATIBILITY
test
245 products
Sort by
Sort by
Standard Transfer Coping (Open Tray) - SGS® Internal Hex CompatibleStandard Transfer Coping (Open Tray) - SGS® Internal Hex Compatible
Standard Transfer Coping (Open Tray) - AB Dent®️ Internal Hex CompatibleStandard Transfer Coping (Open Tray) - AB Dent®️ Internal Hex Compatible
Regular Platform Closed Transfer - Osstem®TS Hexagon CompatibleRegular Platform Closed Transfer - Osstem®TS Hexagon Compatible
Transfer Coping (Closed Tray) Regular Platform (RP) - ADIN CloseFit® Conical CompatibleTransfer Coping (Closed Tray) Regular Platform (RP) - ADIN CloseFit® Conical Compatible
Transfer Coping (Open Tray) Narrow Platform (NP) - NobelActive®️ Conical CompatibleTransfer Coping (Open Tray) Narrow Platform (NP) - NobelActive®️ Conical Compatible
Impression Coping Transfer For Ball Attachment - MIS Seven® Internal Hex CompatibleImpression Coping Transfer For Ball Attachment - MIS Seven® Internal Hex Compatible - Front
Narrow Transfer Coping (Closed Tray) - Ritter® Internal Hex CompatibleNarrow Transfer Coping (Closed Tray) - Ritter® Internal Hex Compatible - Rear
Narrow Transfer Coping (Open Tray) - Zimmer® Internal Hex CompatibleNarrow Transfer Coping (Open Tray) - Zimmer® Internal Hex Compatible - Rear
Narrow Transfer Coping (Open Tray) - Ritter® Internal Hex CompatibleNarrow Transfer Coping (Open Tray) - Ritter® Internal Hex Compatible - Rear
Transfer Coping (Open Tray) - SGS® Internal Hex CompatibleTransfer Coping (Open Tray) - SGS® Internal Hex Compatible
Standard Transfer Coping (Closed Tray) - Zimmer® Internal Hex CompatibleStandard Transfer Coping (Closed Tray) - Zimmer® Internal Hex Compatible
Standard Transfer Coping (Closed Tray) - BioHorizons® Internal Hex CompatibleStandard Transfer Coping (Closed Tray) - BioHorizons® Internal Hex Compatible
Standard Transfer Coping (Open Tray) - Ritter® Internal Hex CompatibleStandard Transfer Coping (Open Tray) - Ritter® Internal Hex Compatible
Standard Transfer Coping (Open Tray) - Implant Direct Legacy® Internal Hex CompatibleStandard Transfer Coping (Open Tray) - Implant Direct Legacy® Internal Hex Compatible
Standard Transfer Coping (Open Tray) - DSI® Internal Hex CompatibleStandard Transfer Coping (Open Tray) - DSI® Internal Hex Compatible
Standard Transfer Coping (Open Tray) - BioHorizons® Internal Hex CompatibleStandard Transfer Coping (Open Tray) - BioHorizons® Internal Hex Compatible
Mini Platform Closed Ttansfer - Osstem®TS Hexagon CompatibleMini Platform Closed Ttansfer - Osstem®TS Hexagon Compatible - Side
Mini Platform Closed Ttansfer - Osstem®TS Hexagon CompatibleMini Platform Closed Ttansfer - Osstem®TS Hexagon Compatible - Side
Mini Platform Open Transfer - Osstem®TS Hexagon CompatibleMini Platform Open Transfer - Osstem®TS Hexagon Compatible - Side
Impression Coping Transfer For Ball Attachment - NobelActive®️ Conical CompatibleImpression Coping Transfer For Ball Attachment - NobelActive®️ Conical Compatible - Front
Impression Coping Transfer For Ball Attachment - GDT Implants®️ Conical CompatibleImpression Coping Transfer For Ball Attachment - GDT Implants®️ Conical Compatible - Front
Frequently Asked Questions

FAQs

A healing cap is a small component used temporarily to cover the implant site, shaping the gum tissue and protecting the implant from debris after surgery. Its main purpose is to facilitate the healing of the gum around the implant. An abutment, on the other hand, is a permanent fixture that connects the dental implant to the crown. It serves as a base for the final restoration and is typically placed after the gum has healed adequately.

Impression copings come in various types, mainly differentiated by the method of impression taking and the type of implant system used. The two primary types are open-tray and closed-tray impression copings. Open-tray copings allow the impression material to set around the coping, and it is removed with the impression tray. Closed-tray copings are removed from the mouth before the impression tray, and a subsequent step is needed to attach the coping to the impression after tray removal.

A healing cap typically stays on a dental implant for about two to six weeks, depending on the patient’s healing process. The duration can vary based on factors like the individual's healing ability, the complexity of the implant surgery, and the dentist's treatment plan. The healing cap remains in place until the soft tissues (gums) have matured enough to proceed with the next step of placing the abutment.

The healing cap of an implant is a small, dome-shaped component that fits over the end of the dental implant. It is used during the healing phase following dental implant surgery to help guide the gum tissue to heal in the correct shape and prevent it from growing over the implant. This cap helps maintain the space needed for placing the abutment and the dental prosthesis later.

These responses are tailored to provide clear, concise, and accurate information about healing caps and impression copings in the context of dental implants. If you need any more details or additional questions, feel free to ask!

In dental implantology, the selection of the right size of impression coping is crucial for achieving accurate and effective final restorations. Impression copings are tools used to create a precise mold of the implant and the surrounding tissues, which is essential for fabricating the final prosthetic component, such as a crown or bridge. The debate over the optimal size of impression coping revolves around whether it should match the diameter of the implant or if the diameter has a significant impact on the outcome of the final restoration.

Selecting the size of the impression coping involves careful consideration of several factors, primarily the planned final restoration's shape and the characteristics of the healing abutment previously used. The healing abutment plays a vital role in forming a natural or physiological emergence profile for the final restoration. Its size selection must take into account the thickness of the patient's gums, the desired aesthetic outcome, and factors such as the amount and location of keratinized tissue.